TCL Temperature-Controlled Logistics Facility

A centralized industrial refrigeration system with a closed-loop glycol network serving a temperature-controlled logistics facility.

Location
Abomey-Calavi, Benin
Company
Fox Cooling
Year
2026
Discipline
Industrial Refrigeration & Hydraulic Engineering

01Overview

Project overview

The TCL facility in Abomey-Calavi, Benin, is cooled by a centralized industrial refrigeration system. Chillers cool a closed loop of 30 % monoethylene glycol, which is pumped through a distribution network to industrial air coolers in the temperature-controlled spaces.

02My role

My contribution

I have been involved in this project since February 2026 as part of the Fox Cooling team, contributing to engineering and design development, technical evaluation, equipment selection and supplier coordination.

The system was engineered by a team. I did not independently design, approve, commission or manage the installation.

03System architecture

How the system works

Chillers cool the glycol; a hydraulic decoupler separates production from distribution; duty/standby pumps with variable frequency drives deliver glycol to the air coolers; gas removal and pressure-holding equipment sit on the return. Hover or tap the labels to highlight each part.

Conceptual illustration
Conceptual schematic: three chillers feed a hydraulic decoupler; duty/standby pumps with variable frequency drives distribute glycol to air coolers in the cold rooms; the return passes an air separator, vacuum degasser and expansion and pressurization equipment. CLOSED-LOOP GLYCOL SYSTEM GLYCOL SUPPLY GLYCOL RETURN CH-1CHILLERCH-2CHILLERCH-3CHILLER PRIMARY PUMPS DUTY / STANDBY VFD DISTRIBUTION PUMPS DUTY / STANDBY · VFD HYDRAULIC DECOUPLING HOT SIDE / COLD SIDE INTERMEDIATE EXPANSION VESSEL COLD SIDE EXPANSION & PRESSURIZATION VACUUM DEGASSER AIR SEP. AIR COOLERS · COLD ROOMS CONCEPTUAL ILLUSTRATION — NOT A PROJECT DRAWING
Figure 1 — Conceptual system architecture: chillers, hydraulic decoupling, duty/standby pumping, glycol distribution and air coolers. Illustrative only, not an approved project drawing.Scroll sideways to see the whole diagram

05Engineering involvement

Areas of engineering involvement

The engineering areas I worked in on this project, marked by the kind of involvement.

  • PerformedWork I carried out myself
  • ContributedTeam work I contributed to

Technical coordination

Performed
  • Equipment comparisons
  • Manufacturer coordination
  • Technical clarifications
  • Datasheet reviews
  • Technical submittals
  • Design development support

Refrigeration engineering

Contributed
  • Centralized glycol refrigeration architecture
  • Cooling requirements
  • Operating temperatures
  • Chiller and air cooler integration

Hydraulic engineering

Contributed
  • Pump technical evaluation
  • Duty/standby configurations
  • Hydraulic distribution
  • VFD integration
  • Hydraulic decoupling

Expansion & pressurization

Contributed
  • Expansion vessels
  • Pressurization equipment
  • Intermediate expansion vessels
  • Vacuum degassing
  • Air separation

Water treatment & preservation

Contributed
  • Glycol corrosion protection
  • Cortec and VEXO inhibitor evaluation
  • Material compatibility considerations
  • Wet preservation strategies

06Equipment

Equipment categories

Chillers

A multi-chiller plant producing the glycol cooling.

Air coolers

Industrial air coolers in the temperature-controlled spaces.

Pumps & drives

Duty/standby pumping arrangements with variable frequency drives.

Hydraulic decouplers

Hot-side and cold-side decoupling between production and distribution.

Expansion & pressurization

Expansion and pressurization systems, with an intermediate vessel on the cold side.

Degassing & air separation

Vacuum degassing and air separation to keep the glycol loop free of gas.

07Engineering considerations

What made this system demanding

  1. Low-temperature glycol operation

    At sub-zero glycol temperatures, fluid properties drive pump selection, heat-transfer performance and freeze protection.

  2. A large closed-loop volume

    A large fluid volume must be held within its pressure limits as temperatures change, which makes expansion, pressurization and gas removal central to the design.

  3. Redundancy and part-load operation

    Duty/standby pumps with variable frequency drives must serve a governing requirement below the connected capacity.

  4. Long-term wet preservation

    The system may stay filled for a long period before operation, so corrosion protection, inhibitor choice and material compatibility have to be assessed early.

  5. International coordination

    Equipment from several manufacturers had to be compared, clarified and coordinated for a project in West Africa.

09Experience gained

Engineering lessons from the project

  • Reading manufacturer datasheets against the actual operating point: glycol, temperature and duty, not catalogue conditions.
  • Seeing how expansion, pressurization and degassing work together as one system in a large closed loop.
  • Comparing pumps and redundancy arrangements on technical grounds as well as cost.
  • Taking long-term preservation and water treatment into account at the design stage, not only at commissioning.

Related academic work

Engineering Assessment and Design Verification of an Industrial Glycol Refrigeration System for a Temperature-Controlled Logistics Facility

My final-year project at the Lebanese University, supervised by Dr. Carine Habchi, studies the same type of system.

No confidential documents, supplier quotations, commercial information or project drawings are reproduced. All diagrams are conceptual illustrations, not approved project drawings.